Tongyi  Double Wall air source heat pump is the best choice for hot water supply of commercial projects, such as hotels, schools, and other large buildings, which need large water volume supply. The circulating heat pump is connected to the water tank with a separate water pump, it will supply hot water and store it in the water tank but not directly to end facilities in case of different water demands.

Capacity Range:

5KW, 10KW,20KW,40KW,80KW

Key Features 

Copeland scroll compressor

World-famous scroll compressor with low energy consumption and high energy efficiency output, which effectively shortens the heating water time and double extends the useful life of the unit. Tongyi heat pump can increase over 20% heating capacity even though it works under severe weather.
Copeland scroll compressor

Internal thread tube in the tube heat exchanger, dual cycle and multipath wavy, coaxial and spiral design

Internal thread tube in the tube heat exchanger, dual cycle and multipath wavy, coaxial and spiral design

Multi-protections

The system runs safely, steadily, and reliably thanks to our full protection: high-temperature protection, compressor overload & overheat protection, power phase sequence & over/under voltage protection, etc.

Multi-protections

EEV, precise flow control

Wide working temperature range, faster and more accurate refrigerant flow control than capillary and mechanical expansion valve. Best choice to achieve higher efficiency and energy-saving.

EEV, precise flow control

Auto-defrosting program and anti-freeze

Intelligent defrosting technology, which can determine the time of defrosting according to the operating conditions of the unit (running time, exhaust temperature), ambient temperature, and thickness of frost, so as to achieve intelligent defrosting when it is necessary, which greatly shortens the defrosting time by more than 20% and ensures the high heating capacity.

Auto-defrosting program and anti-freeze

Flexible Installation

The Cuboid shape module design of the unit makes the project installation save more space.

Flexible Installation

pannel control

Remote control

BMS contact point / Modbus support(with RS485) to Amazon cloud, realize remote control function optional

 

IoT

With IoT technology, we can check the heat pump status remotely. When there is fault occurs, it is easy for us to check the product information and give immediate support to our customers.

With OTA(update over air) technology, If there is an error that happens on the software, we can do the remote service by updating the software online. And when the software has a new version with the function upgraded, as long as we got your permission, we can update the software remotely. 

IOT

High-performance FM

It uses an outer rotor axial flow silent fan with a five-leaf balanced aluminum alloy wind wheel. It has the advantages of corrosion resistance, large air volume, and low noise.

High-performance FM

Patent louvered casing

TONGYI’s patent louvered casing can be better for waterproof, windproof and dust-proof. Patent no.:CN201030670236.9.

Patent louvered casing

Unique hydrophilic fin coil heat exchanger

Large amount for air inletAir exchangers(fin-coil)with hydrophilic coating are strongly anti-corrosive and perform at high efficiency.

Unique hydrophilic fin coil heat exchanger

Overview

Overview

User

User

Quality Control

Quality is taken into account since product design through the whole product life-cycle. With professional design procedure, simulation, and over 30 type tests, from incoming parts inspection to out-going heat pump inspection during production.

Quality Control

R&D

With the Research center, product design department, and product engineering team, we have technical talents with over 20+ years in heat pumps, the development is managed by PLM(Production Lifecycle Management system) with the design procedure. 

R&D

Certificate

Certificate

Specifications

 

TAHW10

TAHW20

TAHW46

TAHW95

TECHNICAL DATA

Nominal Heating Capacity, kW

11

24

46

95

Rated Input Power,kW

2.3

4.9

9.8

19.5

COP

4.7

4.94

4.7

4.9

Power Supply, Volts/Ph/Hz

50 Hz

220/1/50

380/3/50

380/3/50

380/3/50

60 Hz

220/1/60

380/3/60

380/3/60

380/3/60

Refrigerant

R410A

Refrigerant Factory Charge,g

1500

3700

3400*2

5000*2

Rated Outlet Water Temperature,

55

Max. Outlet Water Temperature,

60

Dimensions (Lx Wx H), mm

752x729x916

859x 829x 988

1503x723x 1208

2200x 1005x 1840

Noise Level, dB

56

62

62

70

Cabinet

Powder Painted Galvanized Steel(Option: SUS 304)

IP Rating (Enclosure Class)

IPX4

Safety Device

Compressor Thermal Overload

High & Low Water Temp

High Discharge Temp

Sensor Probe Fault

Throttle Type

Electronic Expansion Valve

Net Wt./Approx. Shipping Wt., kg

97/115

120/141

325/340

650/685

COMPRESSOR

Quantity/Type

1/Scroll

1/Scroll

2/Scroll

2/Scroll

Volts/Phase/Hertz

50 Hz

220/1/50

380/3/50

380/3/50

380/3/50

60 Hz

220/1/60

380/3/60

380/3/60

380/3/60

EVAPORATOR COILS

Fin Type/Tube Type

Hydrophilic  Aluminum Fins/Internal Threaded Tube

CONDENSER

Type

Double Wall Tube in Tube

Water Flow Rate,m3/hr

1.86

4.16

7.88

16.34

Pressure Drop thru Heat Exchanger,kPa

50

Max. Working Pressure-Water Side. kPa

700

Water Connection

DN25

DN4O

DN40

DN75